How long will your batteries last behind your Suntaic inverter?
Describe your system and your average draw, and the calculator returns the usable energy, how many hours you can run, and when the batteries will hit your cut-off.
Many Suntaic kits are sold with about 5 kWh of lithium storage. The calculator starts there, with the modest evening load of a country house: lights, a fridge, a router. Change the values to your own installation.
Suntaic Monitor does this calculation live, with your real consumption: the dashboard shows when the batteries will be full or reach your cut-off. See it in the demo →
The formula
autonomy = capacity × health × (charge − cut-off) × efficiency ÷ (consumption + inverter’s own consumption)
Example with a 5.12 kWh lithium battery: from 95 % to a 20 % cut-off, behind an inverter at 92 % that uses 45 W for itself, with an average load of 250 W: 5.12 × 0.75 × 0.92 ÷ 0.295 ≈ 12 hours.
Why real runtime is often shorter
- One weak cell ends the discharge. The BMS stops the battery when its lowest cell reaches its limit, even if the others still hold energy. A growing cell spread shortens the night.
- The displayed charge drifts. Charge level is tallied from current flowing in and out. Skip full charges for a while and it may be a few points wrong.
- Cold reduces what you can take out. Below about 10 °C a lithium battery delivers less, and many BMS limit the current.
- Peaks cost more than the average. Peaks matter: a 2 kW kettle or pump running a few minutes takes more than the simple average suggests, through losses and current limits.
A home usually draws 100 to 250 W at night and 400 to 1,000 W in the evening. After a few days, the dashboard of your box shows your real figure.