The parcel is open and the inverter is in front of you. A few minutes from now the box should show the charge of your battery. This is what its screen says on the way, and what to do if it stays stuck looking for the inverter.

By the Suntaic Monitor team · 23 November 2026 · 4 min read

In short

  • The box goes into the RS232 port with the supplied cable; the battery cable in RS485 stays where it is.
  • After Save, the screen tells you why WiFi failed: wrong password, network out of range, or no connection.
  • "No reply: check the cable" nearly always comes down to the wrong port or a cable that is not the supplied one.

Three items, two plugs

The parcel holds the Suntaic Monitor, its RS232 cable and a USB-C cable. For power, use any phone charger you have at home.

Look under the inverter. Two communication sockets sit side by side, RS485 and RS232. On many Suntaic Hero inverters the RS485 one is already taken by the battery cable. Leave that cable alone: the box goes into the RS232 port.

Use the supplied cable and no other. It is a special cable made for this port. An ordinary network cable looks the same from outside and must never take its place.

Connect the inverter and the box first, then the USB-C power. The box starts looking for the inverter the moment it is powered, while you take care of WiFi.

WIFI SETUP: giving the box your network

A box that has never been set shows WIFI SETUP and three numbered lines.

  1. 1. On your phone, join the WiFi network, then a name beginning with SuntaicMonitor-. Open the WiFi settings of your phone and choose it. No password is asked.
  2. 2. Open this page: then an address starting with http://. Your phone often opens it without being asked. Otherwise type it in the browser.
  3. 3. Pick your home WiFi and press Save. On the page called "Box WiFi", select your home network (2.4 GHz), enter its password and press Save.

At the bottom, a new box adds First setup: step 1 above.

Suntaic Monitor showing the WIFI SETUP screen: network name, page address and the Save step
WIFI SETUP on a new box.

After Save

The box restarts and the screen changes to Connecting to WiFi, with the name of your network, Please wait, up to 40 s. and If it fails, a setup WiFi opens on its own. If the connection fails, WIFI SETUP returns and its last line gives the reason:

  • Wrong WiFi password? Your router refused the box. Retype the password, minding capitals.
  • Not in range: followed by the network name. The box cannot see that network: router too far or switched off, or a network that only exists on 5 GHz.
  • Could not join followed by the name. Nothing conclusive happened in 40 seconds. Check both points above and try again.

Looking for the inverter

This screen is headed SUNTAIC with LINK on the right. It stays as long as the inverter has not replied. The yellow line under Looking for the inverter is the one to read.

Starting

The first second after power-up. Nothing to do.

A line that begins with Trying

The word Trying is followed by figures that change. The box is going through its settings one after the other to find how your inverter talks.

No reply: check the cable

A full round of attempts got nothing back. The box waits 15 seconds and starts another round, again and again, without any action from you.

0 reads OK

A counter of successful readings. While it shows zero, the inverter has not been heard at all. The moment it goes above zero, port and cable are right.

Supplied crossed cable in inverter RS232 port

Two grey lines that never change. They remind you which cable to use, the one from the parcel, and where it goes.

Suntaic Monitor showing Looking for the inverter with the message No reply: check the cable
The search screen with "No reply: check the cable" and the counter at "0 reads OK".

When No reply does not go away

  • Is the cable in RS232 and not in RS485? The two sockets look identical, and this is the most common mistake. If the battery cable is in RS485, do not move it.
  • Is it the supplied cable? If it was swapped for a network cable, to gain length for example, put the original back. If you need a longer one, write to us.
  • Is a computer or a USB cable connected to the communication ports of the inverter? Remove it.

First values

The header now shows SUNTAIC and the mode of the inverter in capitals, for example ON GRID, OFF GRID, BYPASS or STANDBY, and FAULT if the inverter reports one. The large percentage is the battery charge, with its voltage and current below. On the right, four figures: solar, load, battery (plus when charging) and grid. Lower down, Grid gives the grid voltage, or Grid none when there is no grid, and Inv. the temperature of the inverter. The last line is the address of the box on your network. Type it in a browser to see the full dashboard.

After 12 seconds the screen moves to TODAY for 6 seconds, with Solar, Load, Batt +, Batt - and Grid in kWh, then returns.

A house without WiFi

In a holiday home with the router off, the box still reads the inverter. Since the latest firmware the screen alternates every 10 seconds between the values and the WIFI SETUP steps. This is expected behaviour, not a fault. You can even open the full dashboard on the spot: join the network of the box, open the page and tap "Open the dashboard". Once your own network is back, the box notices within a few minutes and reconnects by itself.

The status light

One short flash every two seconds: everything is fine. Fast blinking: the box is searching for the inverter, or joining WiFi just after power-up.

Still stuck: what to send us

Send us a photo of the screen through the contact page, and the report of the box: on its page, tab Diagnostics, button Download the report.

If the box no longer starts properly, its firmware can be reinstalled from a computer over USB on https://suntaic-monitor.com/reset, with Chrome or Edge and a USB-C cable that carries data. The settings are erased, so WiFi has to be set again.

Common questions

Can I use a normal network cable between the box and the inverter?

No. The supplied cable is a special cable for the RS232 port of Suntaic inverters. Keep it, and write to us if you need a longer one.

The RS485 port is already used by my battery. Where does the box go?

Into the RS232 port next to it. Leave the battery cable in RS485 exactly as it is.

What does "No reply: check the cable" mean?

The box asked the inverter and heard nothing. Check that the supplied cable is in the RS232 port, fully pushed in. The box tries again every 15 seconds.

The screen says "Wrong WiFi password?". What now?

Join the SuntaicMonitor network again from your phone, open the page shown on the screen and retype the password of your home WiFi.

Why does the screen keep going back to WIFI SETUP while it shows my values?

The box is not on a WiFi network. It alternates every 10 seconds between the values and the setup steps. The reading itself is not affected.

Suntaic Monitor box with colour screen used to supervise a Suntaic solar inverterRJ45 RS232 socket and USB-C power socket on the Suntaic Monitor box
The Suntaic Monitor box, real photos. Size, ports and specifications →
Hands-on

See it on your own system

Check your Suntaic system from anywhere in the world

Order Suntaic Monitor. Ships within 3 working days, tested on a Suntaic inverter.

Plug & play: working in about a minute

Order for €59Ships within 3 working days · free cancellation until dispatch
Follow us on FacebookTips, news and real installations from our customers.
Follow